Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Vet Diagn Invest ; 33(5): 1008-1012, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34176384

RESUMO

A 12-y-old, castrated male Pomeranian dog was presented because of mandibular lymph node (LN) enlargement. Physical examination and a complete blood count revealed generalized lymphadenopathy and moderate lymphocytosis. Fine-needle aspirate cytology revealed expansion of medium lymphocytes in the right mandibular LN and expansion of large lymphocytes in the left popliteal LN. Flow cytometry identified 2 aberrant lymphocyte populations in both LNs, namely a CD5+CD45- T-cell population, and a large CD21+ B-cell population. Flow cytometry of the peripheral blood revealed an identical population of aberrant CD45- T cells. The patient was diagnosed with concurrent T-zone lymphoma and leukemia, and B-cell lymphoma. Multi-agent chemotherapy was instituted, and serial clinical and flow cytometric analysis revealed complete remission of the neoplastic B cells, but persistence of the neoplastic T cells and persistent lymphadenopathy. This case affirms the diagnostic value of flow cytometry and reveals a unique limitation of the RECIST criteria.


Assuntos
Doenças do Cão , Citometria de Fluxo , Linfoma Difuso de Grandes Células B , Animais , Biópsia por Agulha Fina/veterinária , Doenças do Cão/diagnóstico , Doenças do Cão/tratamento farmacológico , Cães , Citometria de Fluxo/veterinária , Imunofenotipagem/veterinária , Linfonodos , Linfoma Difuso de Grandes Células B/veterinária , Masculino , Linfócitos T
2.
J Vet Emerg Crit Care (San Antonio) ; 28(4): 317-325, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29901847

RESUMO

OBJECTIVE: To evaluate the technical performance of the turbidimetric ACL-TOP CTS 300 coagulation analyzer (IL) in dogs and cats and to create reference intervals for standard and novel parameters. DESIGN: Coagulation testing results from dogs and cats generated by the IL were prospectively compared with another mechanical clot detection system. Precision was documented and reference intervals were created for prothrombin time, activated partial thromboplastin time, and Clauss fibrinogen and D-dimer values, as well as for the quantitative clot curve parameters (high and low amplitude, delta, and first and second derivative curves). Clot curve signatures containing common artifacts due to lipemia, hemolysis, or preactivation were demonstrated. ANIMALS: Residual frozen plasma from 20 dogs and 10 cats was used for method comparison; prospectively recruited healthy dogs (n = 48) and cats (n = 45) were used for reference interval and precision studies. MEASUREMENTS AND MAIN RESULTS: Bland-Altman analysis showed a proportional positive bias in the IL compared with mechanical clot detection in dogs and a suggestion of a similar pattern in cats. Precision was good and met manufacturer's recommendations for all assays. Reference intervals are reported. Clot curve artifacts were similar in animals to those reported in people. CONCLUSIONS: The turbidimetric system had a slight high proportional positive bias compared with mechanical clot detection. Thus, new reference intervals were generated including for novel parameters generated by clot curve analysis. Some preanalytical errors can be identified by inspection of clot curves. This robust novel technology compares favorably with mechanical endpoint detection methods and can be used in dogs and cats.


Assuntos
Testes de Coagulação Sanguínea/veterinária , Gatos/sangue , Cães/sangue , Animais , Testes de Coagulação Sanguínea/instrumentação , Desenho de Equipamento , Feminino , Masculino , Tempo de Tromboplastina Parcial/veterinária , Estudos Prospectivos , Tempo de Protrombina/veterinária , Valores de Referência
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...